The ratio of the output power from the UPS to the input power from the AC utility in Line mode.
Refers to an unwelcome AC component that can be superimposed on the DC output from a UPS rectifier/charger circuit. AC ripple should be prevented from reaching the battery because it causes internal heating and deterioration of the battery poles.
The electric power furnished by an electric power plant.
The unit of battery capacity.
Automatic Mains Failure Detection is a useful function for standby power generators. A generator fitted with AMF can detect and respond to a mains failure by automatically starting up and becoming a 'mains replacement' for the UPS.
The unit of for electric current.
Is a scheduled test designed to identify any battery weakness before it can cause an online battery failure and system crash. It comprises short simulated and actual discharges of the battery and alarm generation if the battery voltage falls below a preset level during the test.
An AVR regulates voltage to the appropriate level.
Also known as back up or discharge time, battery autonomy is a measure of the time for which the battery will support the critical load during a mains failure. Autonomy is a function of battery charge state, capacity and load size.
Is a useful measure of downtime per year for systems subject to failure and repair. It is defined as the probability of a system being operational at any given time during its working life; A = MTBF/(MTBF + MTTR) Where MTBF = Mean Time Between Failures and MTTR = Mean Time To Repair.
The time provided by battery in a UPS system when AC utility loss.
The current to charging the battery that is regulated from the AC utility by the circuit inside the UPS.
A total loss of electrical power.
UPS systems are often required to integrate with operators' BMS or Building Management Systems so that they can be supervised and managed as part of an overall building management strategy.
A function to adjust the output of UPS. When the voltage is under normal condition then the UPS will boost the voltage higher. When the voltage is over normal condition then the UPS will buck the voltage lower.
A power path around a UPS system. An automatic bypass is used by the UPS to switch its load to the mains if it experiences an overload or internal failure. A manual, maintenance or service bypass allows an engineer to isolate, maintain or remove the UPS without interrupting power to the load.
A power path around a UPS system. An automatic bypass is used by the UPS to switch its load to the mains if it experiences an overload or internal failure. A manual, maintenance or service bypass allows an engineer to isolate, maintain or remove the UPS without interrupting power to the load.
Is a parallel system where the total capacity of the UPS modules is enough to fully support the load, but with no redundant provision. The failure of any one module will therefore cause severe overloading on the rest. Alternatively, the load may be switched to raw mains.
A protective device that interrupts the flow of current when it exceeds a specified value.
The UPS can be started from battery directly without AC utility. Some people also name it as DC start.
UPSs can often communicate with computer equipment in order to allow the UPS to trigger a controlled automatic shutdown of the computer. This is usually done when the mains has failed and the UPS battery power is close to being used up.
The ratio between the crest (peak or maximum) value and the root-mean-square (RMS) value of an alternating current. Some computer power supplies draw current with a crest factor of between two and three.
The function of a circuit or system that maintains a current within its prescribed limits. UPS systems have an electrical current limit that regulates the output current to a value within the UPS limits. Current limiting may occur when a load demanding high inrush current is turned on.
The ratio of the output power from the UPS to the input power from the batteries in Battery Mode.
Normally, it is used for the battery voltage.
On-line UPS system receives mains AC power, rectifies it into DC for conditioning and battery charging, then inverts it into clean AC to supply the critical load. In the event of mains overvoltage or failure the UPS continues to supply the load from its battery with no transfer delay. Provided the mains power disturbance duration is less than the battery autonomy, the event remains invisible to the load.
The double conversion efficiency figure for a UPS is obtained by comparing the output power to the load with the input mains power applied to the UPS, where both figures are in kW. This efficiency improves as the load approaches the maximum UPS capacity, so efficiency can be maximised by running the UPS as near to full load as possible.
Unwanted noise during the operation of a power supply or other electrical or electronic equipment.
It is the fast charging battery system to speed up charging time. For this case, the designer must be expert and use high technology in controlling charging system so battery does not damage.
A battery charging scheme suitable for UPS batteries, designed to maximise battery life.
The number of completed cycles in one second. It is defined as Hertz (Hz). It exists 50 or 60 Hz power system in the world.
Two circuits are ‘galvanically’ isolated if their only connection is a transformer coupling. A standard transformer based UPS design typically does not have galvanic isolation because the neutral line passes from the input via the static bypass switch to the output.
A standby generator is a back-up electrical system that operates automatically. Within seconds of a utility outage an automatic transfer switch senses the power loss, commands the generator to start and then transfers the electrical load to the generator. The standby generator begins supplying power to the circuits. After utility power returns, the automatic transfer switch transfers the electrical load back to the utility and signals the standby generator to shut off. It then returns to standby mode where it awaits the next outage. To ensure a proper response to an outage, a standby generator runs weekly self-tests. Most units run on diesel, natural gas or liquid propane gas.
Distortion of an electrical sine wave caused by the power supplies of certain electronic devices. A mathematical representation of a distortion of a pure sine waveform.
Allow the user to easily exchange UPS batteries without turning off the UPS.
The cord for the AC input of UPS. Normally, there are three wires of Line-Neutral-Ground in it.
The current drawn by any electrical device when power is initially applied. Computer equipment typically draws an inrush current of three to ten times the nominal operating value.
Part of the UPS system that converts DC power back to AC.
The degree to which a device like a UPS can electrically separate its input from its output.
The maximum AC or DC voltage which maybe continuously applied from input to output and/or chassis of a power supply.
1000 volt-amperes. VA is the unit of apparent power, S.
A term relating to current flowing between the AC supply wires and earth ground. The term does not necessarily denote a fault condition. In power supplies, leakage current usually refers to the 60 Hertz current which flows through the EMI filter capacitors which are connected between the AC lines and ground (Y caps).
A hybrid design that attempts to offer a higher level of performance than a conventional off-line system by adding voltage regulation features to the bypass line.
Any electrical device connected to a power source is a 'load'. For a UPS, the load is the amount of current/power required by the attached electronic equipment.
A manually operated transfer switch used to bypass the major electronics in the UPS. When it is enabled then the service engineer can have the repair service without power interruption.
Modular UPS systems are configured by plugging up to five modules into a 19” rack to meet the capacity and redundancy requirement of the application load. This provides more flexibility and scalability than a complete cabinet containing a single standalone system.
A UPS module is a unit that contains all the hardware and software necessary for full system operation. Modules can be paralleled into a redundant solution with no single points of failure.
Mean Time Between Failures (MTBF) is a measure of the average time a device will function before failing. MTBF ratings are measured in hours and indicate the reliability of hardware devices such as UPS equipment.
The average time between a device’s failure and its return to service.
Describes the configuration and redundant capacity of a parallel redundant system. N represents the number of modules needed to meet the critical load and n is the number of extra, redundant modules, referred to as the coefficient of redundancy.
UPS will shutdown itself when the utility fails and there is no load connected to UPS. This feature is to prolong battery life.
Any undesirable electrical signal.
A standard value assigned to a circuit for the purpose of conveniently designating its voltage class.
In an off-line system, the critical load is powered from the raw mains via the bypass line during normal operation. The load is transferred to the UPS inverter output if the mains fails or transgresses preset voltage limits.
A type of uninterruptible power supply that is constantly converting the incoming power from AC to DC and then inverting DC back to AC. This double conversion process prevents power disturbances from reaching protected loads. The UPS batteries will support the load if conditions exceed a set limit.
An abnormally high voltage sustained for an extended period.
Load current is drawn from a voltage source.
Power factor is a ratio defining the relationship between useable power in Watts and total supplied power in VA (Volt Amperes). The power factor imposed by a load on a UPS system can be either lagging or leading. Traditional data centre loads have been lagging, but blade servers, which impose a leading power factor, are becoming increasingly popular because of their dense and flexible processing power. The closer the power factor is to unity, the greater is the power efficiency of the UPS operation.
The ratio of true power to apparent power in an AC circuit. In power conversion technology, power factor is used in conjunction with describing the AC input current to the power supply.
Total loss of utility power: Causes electrical equipment to stop working.
The Power Management Display, visible on the front panel of UPS equipment, allows operators local monitoring and control access to the UPS. It comprises a mimic diagram with LEDs showing the status of the UPS, control keys allowing an operator to manage the UPS, and an LCD display providing more detailed information about UPS events and status. The display also shows information during start-up, shutdown and diagnostic activitie.
Generally segmented by low range (below 5 kVA), mid-range (5–20 kVA) and high range (above 20 kVA).
A circuit used in switching regulated power supplies where the switching frequency is held constant and the width of the power pulse is varied, controlling both line and load changes with minimal dissipation.
UPS that can be mounted in a rack case.
The part of the UPS system that converts AC input power into DC power for feeding the conditioning and inverter components, and charging the back-up battery.
In engineering it means duplication of critical components of a system with the intention of increasing reliability. If one component fails the remaining ones can continue the operation.
Some UPS systems are designed with redundant critical circuits. If a redundant critical circuit fails, its partner UPS module/s can continue to support the full load without interruption. This redundancy within a unit is in addition to any system level redundancy achieved by an N+n parallel configuration of units.
Describes the amount by which the voltage of an AC power source changes. A UPS has poor regulation when its average voltage varies or drifts, or if the voltage varies when a load is applied.
It provides a simple way of providing UPS status information to a location up to 100m from the system, using dry relay contacts.
Electrical noise resulting from some parts of the equipment or wiring acting as a radio antenna. The noise may be large enough to disrupt communications or cause computing errors.
Modular systems can be more accurately matched than traditional standalone UPS to their critical load requirement. This feature is known as ‘Rightsizing’ and is possible for two reasons. Firstly, the modules are available in relatively small capacities, so installing one module more than the load requirement will provide redundancy with minimum excess capacity. Secondly, UPS capacity can be incrementally increased to handle growing load requirements, obviating any need for initial oversizing.
Without adequate protection, a UPS battery can be subjected to AC ripple generated by the rectifier/charger or inverter. This will lead to internal battery temperature increase and deterioration of battery poles.
A serial communications protocol. It may be used between a UPS and a computer to communicate alarm, status or control signals and instructions.
A special cable plugs into the UPS and the computer's serial (RS232) port.
(typically 120 or 230 VAC depending on the country) is carried between two wires, live and neutral, and sometimes a third (ground) wire for safety. The frequency of AC voltage is 50 or 60 Hz depending on the country.
The availability of a UPS system is an important figure of merit. Availability (A) is defined as: A = MTBF/(MTBF + MTTR)It describes the total time for which a system is available for operation as a proportion of the total time for which it is needed. Modern systems can achieve ‘Six Nines’ availability, which means 0.999999 or 99.9999%.
Is a worldwide standard communications protocol. It stands for Simple Network Management Protocol and is used in network management systems to monitor network-attached devices for conditions that warrant administrative attention. UPS systems can be given SNMP connectivity with either an internal plug in card or an external adapter. UPS Ltd's A software can then be used to monitor and manage the UPS from a remote computer either on the enterprise network or across the Internet. A single internal or external SNMP UPS interface can manage multiple modules in a parallel redundant system.
High voltage spikes are a sudden, rapid voltage peak of up to 6,000 volts with duration of 100mS to 1/2cycle. These spikes are usually the result of nearby lightning strikes, but there can be other causes as well. The effects on vulnerable electronic systems can include loss of data and burned circuit boards.
Those are free-standing systems that operate independently.
switch from utility to battery power only when the utility power fails
(see Bypass)
Circuitry consisting of MOVs, capacitors, rod-core inductors etc. for suppressing surges and spikes usually embedded in a power strip.
THDi stands for the Total Harmonic Distortion of the input current waveform. It is generally accepted that the THDi should be kept low to avoid excessive current distortion at the point of common coupling within a building due to the cumulative effect of all connected equipment.
An electrical system possessing three different live voltage lines (phases) with sine wave voltages that are shifted by 120 degrees between each other. The mid-point of the 3 -phases, when present in the system, is called the Neutral.
The amount of time it takes a stand-by or off-line type UPS to sense a power interruption and switch from utility output to inverter output. Normally expressed in milliseconds.
A device used to convert the voltage of AC and/or to galvanically isolate a circuit from its power source
Traditional UPS technology based on inverter transformer that was used for stepping the inverter voltage up to output voltage.
Innovative three-phase technology without transformers
A device which maintains a continuous supply of electric power to connected equipment by supplying power from a separate source when utility power is not available.
A USB cable connects to the USB port on a computer and to the UPS.
User replaceable batteries allow the user to easily exchange UPS batteries. Normally, the battery lifetime is close to 2~3 years.
The unit of measure for voltage.
Transient (short term) over-voltage i.e. spike or peak: Causes wear or acute damage to electronic equipment.
VRLA or Valve Regulated Acid Batteries emit virtually no gas, require no topping up and need no special ventilation apart from that required by local building codes.
The unit of measure for true power. Watts = VA x Power Factor